Malting
> >
A-Type Heat Recovery Unit in beer malting, air flow 1.2million m3/h, in Tsingtao Beer Factory
Air Flow: 1,800,000m3/h,Max. 1,848,000 m3/h
Module Quantity: 196 set
Outline dimension of base: 30158×4150mm 
Material of tube: 3A21X 
Size of tube: φ32×0.8mm 

Tsingtao Beer No.2 Brewery
Tube Type: Elliptic finned-tube
Running Date: 2007 

Tsingtao Beer 100,000t Malting Line 
Air Flow: 1,800,000m3/h,Max:1,848,000 m3/h
Module Quantity: 196 set
Outline dimension of base: 30158×4150mm 
Material of tube: 3A21X 
Size of tube: φ32×0.8mm 
Total heat exchanging area: 21425m2
Total weight of tubes: 46ton
Total weight: 76ton
Inlet temperature of exhaust air: 24~80℃
Inlet temperature of fresh air:  -16~35℃
Temperature rise of fresh air: 0~16℃
Total air pressure drop: 350Pa 
Heat recovering capacity: 4256KW 
Annual coal saving: 4099ton/year 